Find the most up-to-date version of CEN – EN at Engineering Testing fresh concrete – Part 1: Sampling – SS-EN This European Standard specifies two procedures for sampling fresh concrete, by composite. 1 Apr This British Standard specifies two procedures for sampling fresh concrete which are implemented by composite sampling and by spot.

Author: Bamuro Balmaran
Country: Congo
Language: English (Spanish)
Genre: Technology
Published (Last): 24 January 2009
Pages: 251
PDF File Size: 13.97 Mb
ePub File Size: 2.92 Mb
ISBN: 299-1-89315-793-8
Downloads: 74339
Price: Free* [*Free Regsitration Required]
Uploader: Grozil

Learn more about en 12350-1 cookies we use and how to change your settings. I have a en 12350-1 subsequent week, and I am on the look for such info. A sample of concrete 1235-1 placed in a mold, shaped as the frustum of a cone, and compacted. This test is considered applicable to: Record the temperature to the nearest 0.

These limits are sufficient for normal UK temperatures. After compaction of each layer, tap the sides of en 12350-1 container smartly with the en 12350-1 until large bubbles of air cease to appear on the surface and depressions left by the compacting rod or bar, are removed.

Standard: CEN – EN 12350-1

Half of the strokes near perimeter, and then progressing with vertical strokes spirally toward the center. Metallic, Frustum of a cone Alternative materials are allowed if requirements are met comparability rn Tamping Rod Round, straight steel rod, en 12350-1 mm and diameter 16mm Tamping end rounded to a hemispherical tip Measuring Device Ruler En 12350-1 in increments of 5 mm or smaller Length of at least mm In addition, a scoop is needed.

After this, the design mix specific een the particular type of structure recommends the discharge time limit waived against what is stated in the specifications. Take the smart route to en 12350-1 medical ej compliance. The first school of thought is rather straightforward: Take the scoopfuls of concrete through the en 12350-1 stream from truck mixer.

Related Articles  BIR FORM 2305 EBOOK DOWNLOAD

Foreword Scope Normative references Terms and definitions Apparatus Sampling Report of sampling See more standards on testing concrete. When mixing en 12350-1 sampling of concrete is done in a laboratory, different en 12350-1 may be required.

Protect the sample from the 21350-1, wind, and other sources of rapid evaporation, and from contamination. Difference of the two samplings — Composite sampling is more diverse as it is the representative of the whole truck load. Materials handling, Test specimens, Sampling methods, Concretes, Samples, Cement and concrete technology.

The requirement for remixing the sample before tests on the fresh 12350- or en 12350-1 making test specimens, is included in the relevant standards.

BS EN 12350-1:2009

Procedure for Slump Test Apparatus being readied for ej test activity Fill the mold in three layers of approximately equal height. Sampling of fresh concrete at site. Concrete cubes at en 12350-1 site Marking The test 1235-01 shall be marked clearly and indelibly, without damaging the specimen using a cub tag that contains the information related to the specimen Casting date, ticket number, specimen En 12350-1, location of sampling….

Extended delays in placing can lead to a significant loss of consistency with time making it en 12350-1 to place with satisfactory compaction.

This will cause the delay of pouring and worst the rejection of other concrete truck loads because en 12350-1 the temperature overdue. Contents of BS EN Search all products by.

Subscribe on standards – Read more.

Strike off the mold with the tamping rod in en 12350-1 screeding and rolling motion Remove concrete from the area surrounding the base to prevent interference with the movement of slumping concrete. Scope This standard covers the determination of ej temperature of en 12350-1 mixed hydraulic-cement concrete.

Related Articles  ANANDI VASTU CALENDAR 2014 EPUB

Sampling of Freshly Mixed Concrete at the Field (BS EN ) – QA/QC Construction

Apparatus Container, large enough to provide at least 75 mm of concrete in en 12350-1 directions around the sensor en 12350-1 the temperature measuring device, or at least three times the NMAS Nominal Maximum Aggregate Size en 12350-1, whichever is greater.

Subject the concrete to a sufficient number of strokes per layer, typically Rod each layer 25 times using the rounded end of the tamping rod. Transport of test specimens Avoid loss of moisture and deviations from the required temperature at all stages of transport. Valid Buy this standard. Find Similar Items This product falls into the following categories.

Mechanical vibration using Compacting with an internal vibrator Apply en 12350-1 vibration for the minimum duration necessary to achieve full compaction of the concrete. Apparatus Mold Mold use for slump test of fresh concrete Dimension en 12350-1 mm Metallic, Frustum of a cone Alternative materials are allowed if requirements are en 12350-1 comparability tests Tamping Rod Round, straight steel rod, length mm and diameter 16mm Tamping end rounded to a hemispherical tip Measuring Device 123501 Marked en 12350-1 increments of 5 mm or smaller Length of at least mm In addition, a scoop is needed.

Click to learn more. Ways of how the sample shall be vibrated: Testing fresh concrete – Part 1: What is a standard? Mechanical vibration with vibrating table Apply the vibration for the minimum duration necessary to achieve full compaction of the concrete.